BHRLC - B85 W A13 INT. AIRLESS SPRAYING EG-SHEL ENL

  • MSDS: BHRLC
  • Manufacturer: SHERWIN WILLIAMS COMPANY
  • Product Name: B85 W A13 INT. AIRLESS SPRAYING EG-SHEL ENL
  • National Stock Number: 8010-00F007011
Product Identification

Product ID:B85 W A13 INT. AIRLESS SPRAYING EG-SHEL ENL
MSDS Date:01/17/1989
FSC:8010
NIIN:00F007011
MSDS Number: BHRLC

Responsible Party
SHERWIN-WILLIAMS COMPANY
101 PROSPECT AVENUE N.W.
CLEVELAND, OH 44115

Emergency Phone: (216) 566-2917

Info Phone: (216) 566-2902

Cage: 54636

Contractor
SHERWIN-WILLIAMS CO THE
CLEVELAND, OH 44115-1042 US

Telephone: 800-251-2486/216-566-2242

Cage: 54636

Ingredients

ISOPARAFFINIC HYDROCARBONS (NAPHTHA PETROLEUM),

CAS: 64742-48-9

Fraction By Weight: 5%


HYDROTREATED LIGHT DISTILLATE, PETROLEUM

CAS: 64742-47-8

Fraction By Weight: 20%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 10 - 15%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: UNCONSCIOUSNESS, DEATH,
HEADACHE, DIZZINESS, NAUSEA, & LOSS OF COORDINATION. IRRITATION OF
EYES, SKIN & RESPIRATORY SYSTEM. INGESTION: MAY CAUSE NERVOUS
SYSTEM DEPRESSION. EYES/SKIN: REDNE SS, ITCHING OR BURNING
SENSATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: REPEATED/PROLONGED OVEREXPOSURE TO
SOLVENTS CAUSES PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE/MAY CAUSE
ADVERSE EFFECTS TO THE LIVER, & URINARY SYSTEMS. RATS EXPOSED TO
TITANIUM DIOXIDE DUST AT 250 MG/CUM DEVELOPED LUNG CANCER, SUCH
EXPOSURE LEVELS AREN'T ATTAINABLE IN THE WORKPLACE.

First Aid

First Aid:INHALATION: IF AFFECTED, REMOVE FROM EXPOSURE. RESTORE
BREATHING. KEEP WARM/QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY
W/SOAP & WATER. REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
EYES: FLUSH W/ LARGE AMOUNTS OF WATER FOR 15 MINTUES. GET MEDICAL
ATTENTION. INGESTION: GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:74F
Lower Limits:0.9%
Extinguishing Media:CO2, DRY CHEMICAL, FOAM
Fire Fighting Procedures:FULL PROTECTIVE EQUIPMENT/SCBA. WATER SPRAY
MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZLES ARE PREFERABLE.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. WATER MAY
BE USED TO COOL CLOSED CONTIANERS TO PREVENT PRESSURE BUILD-UP,
AUTOIGNITION &EXPLOSION WHEN EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE &
REMOVE WITH INERT ABSORBENT.

Handling

Handling and Storage Precautions:DON'T INCINERATE CLOSED CONTAINER.
AVOID BREATHIGN VAPOR/SPRAY MISTS. USE ONLY W/ADEQUATE VENTILATION.
CONTENTS ARE FLAMMABLE.
Other Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE. DON'T TAKE
INTERNALLY. KEEP OUT OF THE REACH OF CHILDREN. USE APPROVED
BONDING/GROUNIDNG PROCEDURES. INTENTIONAL MISUSE BY DELIBERATELY
CONCENTRATING/INHALING TH E CONTENTS CAN BE HARMFUL.

Exposure Controls

Respiratory Protection:IF >TLV, WEAR A PROPERLY FITTED ORGANIC
VAPOR/PARTICULATE RESPIRATOR APPROVED BY NIOSH/MSHA. WHEN
SANDING/ABRADING DRIED FILM, WEAR DUST/MIST RESPIRATOR APPROVED BY
NIOSH/MSHA.
Ventilation:LOCAL EXHAUST: PREFERABLE. MECHANICAL: ACCEPTABLE TO KEEP
EXPOSURES Protective Gloves:RECOMMENDED
Eye Protection:SPECTACLES W/UNPERFORATED SIDESHIELDS
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
THIS COATING MAY CONTAIN MATERIALS CLASSIFIED AS NUISANCE PARTICULATES,
TITANIUM DIOXIDE, CALCIUM CARBONATE, WHICH MAY BE PRESENT AT
HAZARDOUS LEVELS. WT PER GAL: 8.7-14.2 LB/GAL.

Chemical Properties

Boiling Pt:B.P. Text:240-416F
Vapor Density:>AIR
Spec Gravity:1.05-1.71
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:45-68%

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HEAT, ELECTRICAL EQUIPMENT, SPARKS, OPEN
FLAME, & HOT SURFACES
Hazardous Decomposition Products:CO, CO2

Disposal

Waste Disposal Methods:WASTE FROM THIS PRODUCT MAY BE HAZARDOUS AS
DEFINED UNDER RCRA. WASTE MUST BE TESTED FOR IGNITABILITY TO
DETERMINE THE APPLICABLE EPA HAZARDOUS WASTE NUMBERS. INCINERATE IN
APPROVED FACILITY. DISPOSE OF IN ACCORDANCE W/FEDERAL,
STATE/LOCALREGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.